Hundreds of identical downstream alerts fire when the database becomes unavailable. The team wants notifications suppressed for downstream symptoms while the root-cause alert fires. Which mechanism fits?

Published
  1. A dashboard panel hidden from viewers
  2. A permanent silence for the entire application
  3. A recording rule with a shorter interval
  4. An Alertmanager inhibition rule matching the relevant dependency labels